Tender For supply of flexible wire 7 slash 22 sq mm copper isi mark , pvc insulation tape 20 mm , fan capacitor 2 point 5 mfd isi mark , casing n caping 25mm , pvc copper wire 1 point 0 sq mm single core isi make , pvc copper wire 1 point 5 sq mm single core isi make , pvc mcb box 2 way , pvc mcb box 3 way , pvc mcb box 4 way , pvc mcb box 6 way , pvc mcb box 8 way , nails assorted size 1 inch , nails assorted size 1 and half , nails assorted size 2 inch , nails assorted size 2 and half , nails assorted size 3 inch , nails assorted size 4 inch , thinner 01 ltr btl , lime quick 09 kg bag , painting brush 4 inch , painting brush 3 inch , painting brush 2 inch , wall putty , acrylic sheet 6 feet 4 feet 3mm , glass putty , hacksaw blade , binding wire , ms hinges 100 mm , ms hinges 150 mm , ms hinges 200 mm , nut and bolt full thread 6 inch long , pvc bib tap 15 mm , pvc connection pipe 15 mm hot and cold , pillar tap 15 mm cp , gi union 15 mm isi mark , gi socket 15 mm isi mark , gi socket 20 mm isi mark , gi socket 25 mm isi mark , gi union 20 mm isi mark , gi union 25 mm isi mark , gl nipple 15 mm 6 inch long isi mark , gl nipple 20 mm 6 inch long isi mark , gi nipple 25 mm 6 inch long isi mark , gate valve 15 mm brass , gate valve 20 mm brass , gate valve 25 mm brass , gate valve 40 mm brass , gate valve 50 mm brass , gi tee 15 mm isi mark , gl tee 20 mm isi mark , gl tee 25 mm isi mark , gi reducing tee 15 by 20 mm isi mark , gi reducing tee 20 by 25 mm isi mark , gi reducing socket 15 by 20 mm isi mark , gi reducing socket 15 by 25 mm isi mark , teflon tape , tank nipple 15 mm , tank nipple 20 mm , tank nipple 25 mm , angular cock cp 15 mm , stop cock cp 15 mm , gi elbow 15 mm isi mark , gi elbow 20 mm isi mark , gi elbow 25 mm isi mark , m seal , waste pipe for whb , urinal pot for gents , pvc pipe 110 mm dia 10 feet long , pvc tee 110 mm , pvc socket 110 mm , pvc elbow 110 mm , pvc sealent , urinal pipe 32 mm
Tender For auction sale of rolling stock - pl no.98111061, condemned and over aged bg-8 wheeler icf coach 2 nos. with all available ferrous non-ferrous wooden fittings thereon but excluding the following rc items. 1}coach no. special repair cn 046245 (year built 2004), ds-8 no. 334714 dt 31.03.26, mechanical rc items as per sse/c&w/srr letter no.s-98/coach condemnation/rc items dt.04-11-2025 , coach no.srcn 046245 1] complete bogie arrangements including wheel sets 2 nos, 2] buffer plunger and casing 4 nos 3] cbc/screw coupling set [draw bar with hook, draft gear assembly] 2 set, 4] center pivot 2 nos. 5] bogie mounted brake cylinder 4 nos, 6] distributer valve complete full set 1 set, 7] wearing piece( bronze) and plate 4 nos each, 8] auxiliary reservoir 200 l. 1 no 9] main doors -4 nos 10] water tank-4 nos 11] cut off angle cock -4 nos 12] dirt collector- 2 nos 13] non return valve(fp)- 1 no, electrical rc items as per sse/electrical/srr letter no.elg/srr/6a dt.09.09.25. 1] bldc fan 400 mm-27 nos. 2]9w led lamp-26 nos. 3]2w lamp -8 nos 4]eml- 4 nos 5]mobile charger socket-18 nos. 6] regulator 4.5 kw- 1 no 7]vrla battery with tray-19 nos. 8] battery tray- 4 nos.9] rotary switch with panel board- 1 no 10] alternator to regulator wire ( copper ) -1 kg 11] one alternator(4.5 kw) & one set of axle pulley ( with bogie), 2} coach no. special repair cn 046213, (year built 2004) ds-8 no. 334715 dt 31.03.26, mechanical rc items as per sse/c&w/srr letter no.s-98/coach condemnation/rc items dt.04-11-2025 , coach no.srcn 046213 1] complete bogie arrangements including wheel sets 2 nos, 2] buffer plunger and casing 4 nos 3] cbc/screw coupling complete set [draw bar with hook, draft gear assembly] 2 set, 4] bogie mounted brake cylinders- 4 nos 5] distributer valve complete full set 1 set, 6] wearing piece( bronze) and plate 4 nos each, 7] auxiliary reservoir 200 l. 1 no 8] main doors -4 nos 9] water tank-4 nos 10] cut off angle cock -4 nos 11] dirt collector- 2 nos 12] non return valve(fp)- 1 no, electrical rc items as per sse/electrical/srr letter no.elg/srr/6a dt.25.07.25. 1] bldc fan 400 mm-27 nos. 2]9w led lamp-26 nos. 3]2w lamp -8 nos 4]5w westibal 2 nos 5]eml- 4 nos 6]mobile charger socket-18 nos. 7] regulator 4.5 kw- 1 no 8]vrla battery with tray-19 nos. 9] battery tray- 4 nos.10] rotary switch with panel board- 1 no 11] alternator to regulator wire ( copper ) -1 kg, custodian sse/ c&w/ shoranur.
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For procurement of water supply materials as per demand — ulub municipal council, joda - work of for several work as per demand in ulb, ac pressure pipe 10 inch as per nit, ac pressure pipe 8 inch as per nit, ac pressure pipe 6 inch as per nit, ac pressure pipe 4 inch as per nit, ac pressure pipe 3 inch as per nit, gi pipe 4 inch as per nit, gi pipe 3 inch as per nit, gi pipe 2 inch as per nit, pvc pipe 4 inch as per nit, pvc pipe 3 inch as per nit, pvc t 2 inch as per nit, pvc t 3 inch as per nit, pvc t 4 inch as per nit, gi band 2 inch as per nit, gi band 3 inch as per nit, gi band 4 inch as per nit, gi band 6 inch as per nit, gi elvo 02 inch as per nit, gi elvo 03 inch as per nit, gi elvo 04 inch as per nit, gi socket 2 inch as per nit, gi socket 3 inch as per nit, gi socket 4 inch as per nit, gi socket 6 inch as per nit, siluce valv 2 inch as per nit, siluce valv 3 inch as per nit, siluce valv 4 inch as per nit, siluce valv 6 inch as per nit, telpice ci 3 inch as per nit, telpice ci 4 inch as per nit, telpice ci 6 inch as per nit, telpice ci 8 inch as per nit, reduicer ci 02*03 inch as per nit, reduicer ci 03*04 inch as per nit, reduicer ci 03*06 inch as per nit, reduicer ci 03*08 inch as per nit, reduicer ci 08*04 inch as per nit, e-band ci 3 inch as per nit, e-band ci 4 inch as per nit, e-band ci 6 inch as per nit, e-band ci 8 inch as per nit, nut bolt 1.5 inch as per nit, nut bolt 4 inch as per nit, nut bolt 6 inch as per nit, nut bolt 8 inch as per nit, nut bolt 10 inch as per nit, starter bentax 15 hp as per nit, starter bentax 20 hp as per nit, panel borad complete as per nit, starter oil per liter as per nit, main switch 63 amp with cut out as per nit, claimb all size as per nit, cable 04 mm copper as per nit, cable 06 mm copper as per nit, summbersible motor pump 7.5 hp as per nit, summbersible motor pump 10 hp as per nit, d joint with rubber ring complete 3 inch as per nit, d joint with rubber ring complete 4 inch as per nit, d joint with rubber ring complete 6 inch as per nit, d joint with rubber ring complete 8 inch as per nit, d joint with rubber ring complete 10 inch as per nit, autocut, non reutrn valve 3 inch as per nit, non reutrn valve 4 inch as per nit, flench ci 3*4 inch as per nit, flench ci 4*4 inch as per nit, flench cut wali 03*04 inch as per nit, flench cut wali 04*04 inch as per nit, rubber flench 3 inch as per nit, rubber flench 4 inch as per nit, rubber flench 5 inch as per nit, dent ci all type 3 inch as per nit, dent ci all type 4 inch as per nit, dent ci all type 6 inch as per nit, union shocket 2 inch as per nit, nipple 03*24 inch as per nit, valve iron 2 inch as per nit, valve pital 2 inch as per nit, flench gi 2 inch as per nit, t ci 3 inch as per nit, t ci 8 inch as per nit, gate valce 2 inch as per nit, galen 3 inch as per nit, galen 4 inch as per nit, sada water toti plastic as per nit, pvc water tank 500 liter as per nit, pvc water tank 1000 liter as per nit, single phase motor 1 hp as per nit, single phase motor 1.5 hp as per nit, ringga 1 inch as per nit, motor tuchan as per nit, pannel board 50 number as per nit, pannel board 60 number as per nit, ringga nojal 1 inch as per nit, ringga nojal 1.25 inch as per nit, pvc pipe 8t half inch as per nit, pvc elvo half inch as per nit, pvc socket half inch as per nit, brass elvo half inch as per nit, brass socket half inch as per nit, tape nipple half inch as per nit, t half inch as per nit, brass t half inch as per nit, pvc pipe 8t 1 inch as per nit, pvc elvo 1 inch as per nit, pvc socket 1 nch as per nit, brass elvo 1 inch as per nit, brass socket 1 inch as per nit, tape nipple 1 inch as per nit, t 1 inch as per nit, brass t 1 inch as per nit, pvc pipe 8t 0.75 inch as per nit, pvc elvo 0.75 inch as per nit, pvc socket 0.75 nch as per nit, brass elvo 0.75 inch as per nit, brass socket 0.75 inch as per nit, tape nipple 0.75 inch as per nit, t 0.75 inch as per nit, brass t 0.75 inch as per nit, pvc pipe 1.25 inch as pernit, steel toty as per nit,
Tender For supply of desert cooler iron body, size 26 inch x 26 inch x 36 inch, tank capacity-45- 50 litre . cooler motor size- 450mm, copper winding single phase 230v, 50 hz, 1370 rpm, 145 watt, three no. of step for fan speed control with four iron leg, summersable pump, wooden wool pad , air delivery 3000-4000 cube meter per hour with warranty of 01 year. [ warranty period: 12 months after the date of delivery ] ]
Tender For stage/rate contract for supply of key material/equipments required for operation/maintenance of 33kv lines and 33/11-6.6 kv receiving stations valid for the financial year 2026-27 or till finalization of next stage contract - power transformers, supply of transformer oil as per is: 335-1993 with latest amendments thereof, supply of buchhloz relay for 33/11-6.6 -6.6 kv transformer protection (10mva / 6.3 mva/ 5mva) as per is 3637:1966, supply of winding temperature indicator (wti) for 33/11-6.6 kv power transformer (10 mva / 6.3/ 5 mva ) as per relevant is 5561 standard., supply of oil temperature indicator (oti) for 33/11-6.6 kv for power transformer (10 mva / 6.3/ 5 mva )as per relevant is 5561 standard., supply of cork sheet 6 mm as per relevant is 5561 standard., supply of old sarees/dhoti cloth, supply of gaskets suitable for power transfomers, 33kv ct&pt, supply of 33/11-6.6kv power transformer (10/6.3/5 mva)bush rods with copper washers as per relevant is 3347 standard., hv side, lv side, supply of 33/11-6.6kv power transformer (10/6.3/5 mva)bushes as per relevant is 3347 standard., hv side, lv side, supply of 11 kv spout bushes (indoor type) conforming to relevant standards ammended up to date, supply of mechanical plunger (conforming to relevant standards ammended up to date ) for, 11 kv breakers (both incoming & outgoing), 33 kv vcbs both indoor & outdoor type, supply of 11 kv partition insulators/ bushes with inbuilt studs of required size conforming to relevant standards ammended up to date as per directions of site engineer, supply of dc connector for 11 kv panels conforming to relevant standards ammended up to date, supply of breather conforming to latest is 3202 (ammended up to date) for 10mva/ 6.3mva/ 5/ 3.15 mva., supply of silica gel as per is :3202, supply of o-ring oil sealing of sizes for power transformer bushes (hv/lv) as per is 3202., supply of galvanised iron angle/channel/flat per is :2062 grade "a" of sorts and sizes, g i channel 100x50x50x6 mm, g i channel 75x40x40x6 mm, g.i angle iron 65x65x6 mm, g.i angle iron 50x50x6 mm, g.i flat iron 40x6/ 50x6 mm, supply of arching horns (set of three pieces) for power transformer, supply of g.i bolt full thread of sorts and sizes with washers and nuts of different sorts and sizes, supply of 33kv current transformer (3-core) of reputed make,outdoor oil cooled, single phase (comprising of 3 no.) (as per is 2705 -1992 having ratio of is (is 2165, is 2705(i-iv), is 2099, is 5621, is 2071, is 335, is 13947(part i), iec 185,iec 270, iec 44(4), iec 171, iec 60, iec 8263, iec 815, indian electricity rules 2010), 400-200/5-5-5 a, 300-150/5-5-5 a, 250-125/5-5-5 a, 200-100/5-5-5 a, supply of 11 kv c.t.(2-core/3-core) of reputed make suitable for 11kv vcb panels (comprising of 3 no.) as per is (is 2165, is 2705(i-iv), is 2099, is 5621, is 2071, is 335, is 13947(part i), iec 185,iec 270, iec 44(4), iec 171, iec 60, iec 8263, iec 815, indian electricity rules 2003) having ratio:-, 800-400-200/5-5a, 750-375-187.5/5-5a, 600-300-150/5-5a, 400-200-100/5-5a, 200-100/5-5a, 150-75/5-5a, 100-50/5-5a, 50-25/ 5-5a, 33kv and 11kv outdoor type potential transformer, supply of 33kv potential transformer (comprising of 3 no.) of ratio 33kv/ 3 / 110v / 3 ,single phase,outdoor oil cooled, dead tank type pt as per is:3156 -1992, supply of 11kv potential transformer 11kv/ 3 / 110v / 3 three phase box type (combo unit) as per is :3156-1992, supply of 11kv potential transformer (comprising of 3 no.) 11kv/ 3 / 110v / 3 single phase seperate type as per is :3156-1992, 11kv and 33kv vcbs, supply of master trip relay 24-50 v rel 615 abb ied suitable for 11kv vcb switch gear panels (compitable for electric feild, pascal, scheinder, abb, essan l&t or any other equilant make), supply of digital protection relay adr 141c, rel 615 /abb ied,model no. er113 2 o/c + 1 e/f with high trip (mit113), auxiliary voltage = 0-36 volt conforming to iso 9001:2008 standards (compitable for electric fe
Tender For supply of 220 amps diesel welding generator with electrical start lombardini, 15 ld 440 diesel engine+ ws220 dc alternator- complete trolley mounted set with 5 liter fuel tank ,battery, minimum 15 meter copper welding cable, earthing cable .plastic shield ,suitable for welding 5 mm rod and auxiliary ac overall rated power output of 7.5 kva or more. make: amer nsm india pvt ltd, honda, miller, kirloskar, kohler or equivalent. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh